Quick Enquiry
WhatsApp Connect through Email

Services

BIS Certification for Fire Doors and Assembly IS 3614

Fire Doors And Assembly

In buildings, fire safety is not just a regulatory requirement; it is a crucial measure for saving lives. One of the most important elements of passive fire protection systems is the fire door assembly. These assemblies help contain fire and smoke, enabling safe evacuation and reducing damage.

To ensure performance and reliability, the Bureau of Indian Standards (BIS) has established specifications through the Indian Standard IS 3614. This standard requires manufacturers to obtain ISI certification for fire doors and assemblies, ensuring their products meet national safety and quality standards.

Let's explore everything you need to know about ISI mark certification for fire doors and assemblies, the Indian Standard for these products, and the steps you can take to achieve compliance.

Importance of ISI Certification for Fire Doors and Assemblies 

The ISI mark certification for fire doors and assemblies is essential as it guarantees that these products have been tested for fire resistance and adhere to stringent performance standards. Certification under IS 3614 is increasingly required for government procurement, smart city infrastructure, green building compliance, and projects governed by fire safety regulations. This certification not only ensures reliable performance during fire emergencies but also confirms compliance with national building codes and enhances market credibility. 

Key Requirements of Indian Standard IS 3614

Indian Standard IS 3614, titled “Fire Check Doors — Specification,” outlines the requirements for the construction, performance, and testing of fire door assemblies used in various types of buildings. The standard is divided into two parts:

Part 1: General requirements for construction and performance 

Part 2: Testing for fire resistance and criteria for integrity and insulation 

  1. Construction Guidelines: Fire doors must be constructed using fire-rated materials. The design should ensure that door frames are securely sealed, resist warping and deformation under heat, and maintain structural integrity for a specified duration (typically 30, 60, 90, or 120 minutes).
  2. Fire Testing Parameters: According to IS 3614 Part 2, fire resistance tests evaluate two main aspects: Integrity, which requires that the door must not allow flames or hot gases to pass through, and Insulation, which limits heat transfer to the non-fire side. The doors are tested in a vertical furnace to replicate real fire conditions.
  3. Marking and Identification: Products that conform to IS 3614 must display clear markings, including the manufacturer's details, fire rating (in minutes), year of manufacture, and the ISI mark (after approval from the Bureau of Indian Standards, BIS).

This standard is crucial for manufacturers supplying fire doors to residential buildings, commercial complexes, industrial plants, hospitals, hotels, high-rise structures, and public infrastructure.

BIS Certification Process for Fire Doors and Assembly

To obtain the ISI mark certification for Fire Doors and Assembly, manufacturers must undergo a thorough process under the ISI certification scheme:

  1. Application Submission: Submit the completed application form with necessary documentation to BIS.
  2. Document Review: BIS evaluates the submitted documents to verify accuracy and completeness.
  3. Factory Inspection: BIS officials conduct on-site inspections to assess manufacturing processes and quality control systems.
  4. Sample Testing: Product samples are collected and tested at BIS-approved laboratories to verify compliance with Indian standards.
  5. Certification Grant: Upon successful inspection and testing, the BIS issues the certification, allowing the use of the ISI Mark. 

Documents Required for BIS Certification 

To apply for ISI Certification for Fire Doors and Assembly, manufacturers must provide the following documents:

 Completed application form

 Detailed manufacturing process information

 Quality control plans and test reports

 Factory layout and equipment details

 Product specifications and technical details

 Business registration proof

 Declaration of conformity to Indian standards

Additional documentation may be required based on product specifications and environmental regulations.

BIS ISI Mark Certification Costing And TimelineBIS ISI Mark Certification Costing And Timeline

To Know The Process in Detail, Please Visit:

Under BIS Registration Products ISI and CRS

Conclusion

In a country experiencing rapid urban growth and infrastructure expansion, the demand for certified fire safety systems has become increasingly critical. By adhering to the Indian Standard IS 3614, manufacturers of fire doors and assemblies not only comply with legal requirements but also play a vital role in creating safer environments. 

Suppose you are a manufacturer or stakeholder in the fire safety or construction industry. In that case, obtaining ISI certification for Fire Doors and Assemblies is an essential step in positioning your product as reliable, tested, and compliant. If you need assistance with the BIS certification process for IS 3614, the EVTL India team can guide you through every step, from the application process to lab testing and final approval. Contact us today to get started.

Free Call Back

Why Choose EVTL INDIA

Expertise in Indian Regulatory Standards

End-to-End Support

Trusted by Top Indian & Global Brands

Fast Processing & Transparent Pricing

Strong Liaison with Indian Authorities

Company Profile